The 410 063 has been designed to correct the problem that occurs when an original vehicle sender is not available to match a particular gauge and vise versa.

27 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

Sender/Gauge Corrector Module 12/24vdc

PN: 410 063

GENERAL

The 410 063 has been designed to correct the problem that occurs when an original vehicle sender is not available to match a particular gauge and vise versa.

Another example is where the fuel level sender in an LPG tank needs to be used to accurately drive the original (petrol) fuel gauge in a vehicle. Alternately, the unit could be automatically switched in to circuit when the changing between petrol & gas.

It can also ‘copy’ the signal from an existing gauge/sender combination so that the fuel level may also be observed at a different location. In this case one sender can be used to drive three or four matching gauges.

Because the unit is effectively a ‘resistance converter’ it can also be used on temperature or pressure gauges to correct where the original sender is no longer available for a gauge.

A further advantage is the 8 point conversion curve built in to the unit. This allows it to be used where the resistance graph is a curve, as in large and irregular shaped fuel tanks on trucks and off-road vehicles.

Setting up is extremely simple and can be done on site with almost all applications. Alternately, the modules can be pre-programmed if neccessary to fit a particular application.

NOTES

This unit can only be used with resistive senders, not capacitive senders.

The unit will not work with bimetallic gauges using mechanical regulators as it needs a constant supply voltage.

The unit will not work if supply to it fails or the gauge or sender fails.

CONNECTIONS

Term no. 5 -Ignition +Ve

Term no. 6 -Ground

Term no.3 -Input Resistance/Gauge

Term no.4 -Output to Gauge

SPECIFICATIONS

Protection:  IP52 Rated case – terminals to be pointing down to prevent ingress of water

Dimensions:  68 x 30 x 73mm deep, overall box dimensions

Mounting:  Hole centers…83mm, Mounted Height…35mm. Box with plug & wiring allow 110+mm depth.

Voltage:  12/24vdc negative ground, 30mA typical quiescent current draw

Input:  Resistive only. 0-12VDC or 0-24VDC (235 ohm pull up resistor included)

Output rating:  Resistive only. 0-12VDC or 24VDC. (Pull up resistor not required)

 